AE-UV1601 series
Introduction:
UV1601 Series are advanced Double Beam design consisting of 3 models: UV1601, UV1601A, UV1601S. All the 3 models are Stand-alone models: UV1601 with 1.8nm fixed bandwidth, UV1601A with 1nm bandwidth and UV1601S with 0.5/1.0/2.0/4.0nm variable bandwidth. Except bandwidth, other specifications of the 3 models are almost the same.
The two detectors are measuring sample and reference respectively simultaneously for optimizing measurement accuracy. Basic Modes: Absorbance, Transmittance, Quantitative, Kinetics, Multi-wavelength, Wavelength Scan, DNA/Protein test, Utility.
Technical Specifications:
Model: UV1601
Optical System: Double Beam (1200 Lines/mm Grating)
Wavelength Range: 190-1100nm
Band Width: 1.8nm
Wavelength Accuracy: ±0.3nm
Wavelength Repeatability: 0.2nm
Photometric Accuracy: ±0.3%T
Photometric Repeatability: 0.2%T
Photometric Display Range: 0-200%T, -0.3-3.0A, 0-9999C
Stability: 0.001A/h @ 500nm
Baseline Flatness: ±0.001A
Noise: ±0.001A
Stray Light: ≤0.05%T @220nm, 360nm
Data Output Port: USB
Printer Port: Parallel Port
Display: LCD (320*240 Dots )
Lamps: Deuterium Lamp & Tungsten Halogen Lamp
Detector: Silicon Photodiode
Software: UV PC Software
Packing Size & Weight: 860×660×465mm & 35/37kg
Model: UV1601A
Optical System: Double Beam (1200 Lines/mm Grating)
Wavelength Range: 190-1100nm
Band Width: 1nm
Wavelength Accuracy: ±0.3nm
Wavelength Repeatability: 0.2nm
Photometric Accuracy: ±0.3%T
Photometric Repeatability: 0.2%T
Photometric Display Range: 0-200%T, -0.3-3.0A, 0-9999C
Stability: 0.001A/h @ 500nm
Baseline Flatness: ±0.001A
Noise: ±0.001A
Stray Light: ≤0.05%T @220nm, 360nm
Data Output Port: USB
Printer Port: Parallel Port
Display: LCD (320*240 Dots )
Lamps: Deuterium Lamp & Tungsten Halogen Lamp
Detector: Silicon Photodiode
Software: UV PC Software
Packing Size & Weight: 860×660×465mm & 35/37kg
Model: UV1601S
Optical System: Double Beam (1200 Lines/mm Grating)
Wavelength Range: 190-1100nm
Band Width: 0.5nm/1.0nm/2.0nm/4.0nm
Wavelength Accuracy: ±0.3nm
Wavelength Repeatability: 0.2nm
Photometric Accuracy: ±0.3%T
Photometric Repeatability: 0.2%T
Photometric Display Range: 0-200%T, -0.3-3.0A, 0-9999C
Stability: 0.001A/h @ 500nm
Baseline Flatness: ±0.001A
Noise: ±0.001A
Stray Light: ≤0.05%T @220nm, 360nm
Data Output Port: USB
Printer Port: Parallel Port
Display: LCD (320*240 Dots )
Lamps: Deuterium Lamp & Tungsten Halogen Lamp
Detector: Silicon Photodiode
Software: UV PC Software
Packing Size & Weight: 860×660×465mm & 35/37kg